LIAPHEN™ Protein C
- Immunoturbidimetric assay for the quantitative determination of Protein C Antigen
- Ready to use liquid reagents with excellent stability.
- Calibration plasma and two control levels (normal and pathologic) available
- Applications (CE) for all common coagulation analyzers available
Ref. 120003 (4x2.3 mL) >>> IFU
LIAPHEN™ vWF Antigen
- Immunoturbidimetric assay with ready-to-use liquid reagents for the quantitative determination of von Willebrand factor (vWF) antigen
- No interference from rheumatoid factor up to at least 750 IU / mL
- Very good reagent stability after opening: 4 weeks at 2-8°C or up to 15 days on board of the analyzer (depending on analyzer used)
- Applications (CE) for all common coagulation analyzers available
-
Convenient filling size - up to 60 tests per vial*
-
Validated applications available for all common analyzers
Ref. 120206 (4x6 mL) >>> IFU
LIAPHEN™ Free Protein S
- Immunoturbidimetric assay for the determination of Free Protein S Antigen
- Suitable for all coagulation analyzers.
- Liquid reagents, ready to use.
- Excellent stability of reagents: 2 weeks on board, 4 months at 2 to 8°C
Ref. 120004 (4x3 mL) >>> IFU
LIAPHEN™ AT
- Immunoturbidimetric assay with ready-to-use liquid reagents for the determination of Antithrombin antigen, suitable for all common coagulation analyzers
- Results in % traceable to the WHO standard, direct comparability with Antithrombin activity tests
- No hook effect for antithrombin antigen up to 200%
- No interference by heparin (UFH / LMWH) up to 2 IU/mL and by DOACs (e.g. Dabigatran, Rivaroxaban)
Ref. 120008 (2x1.5 mL) >>> IFU
LIAPHEN™ Fibrinogen
- Immunoturbidimetric assay for immunological determination of Fibrinogen on coagulation analyzers
- Ready to use reagents with high stability: at least one week on board (depending on analyzer), 6 months at 2-8°C
- Two control levels (normal and pathological) available
- Applications (CE) available for all common coagulation analyzers
- Results in g/L, mg/dL traceable to WHO Standard, directly comparable to Fibrinogen activity assays
- Measurement range: up to 6 g/L (600 mg/dL) or up to 24 g/L (2.400 mg/dL) with postdilution respectively
- No interference by direct Thrombin and Xa inhibitors and Heparin (UFH/LMWH) up to 2 IE/mL
Ref. 120102 (4x5 mL) >>> IFU
Calibrators & Controls
BIOPHEN Plasma Calibrator
222101 (12x1 ml) >>> Insert
BIOPHEN Normal Control Plasma
223201 (12x1 ml) >>> Insert
BIOPHEN Abnormal Control Plasma
223301 (12x1 ml) >>> Insert